Common fault knowledge of edible oil filling machine

02/05/2020
image

1. After the controller is started, the oil is discharged from the nozzle, but the controller does not measure
solution:
Introspect whether the signal line is damaged or disconnected, if it is disconnected, connect it according to the original color, or change it; if the platinum resistance is damaged, please change it if it is damaged; if the temperature is displayed above 120 ℃, then Clarified that the temperature signal wire is short-circuited or disconnected; if the temperature is displayed as -20 ° C, the temperature signal wire is connected incorrectly, please reconnect. If the temperature display does not fluctuate, it indicates that the platinum resistance has achieved results, please change it.
2. The edible oil filling nozzle does not go down
3. Nozzle does not go down
4. The oil output does not fluctuate during filling, more and less
The edible oil filling machine should be scrubbed once a week, especially in places that are not easy to clean in ordinary use or wiped with compressed air.